  Datasheet File OCR Text:
 MEAN WELL
SWITCHING POWER SUPPLY
ISO-9001 CERTIFIED MANUFACTURER
.LOW COST, HIGH RELIABILITY .105C OUTPUT CAPACITOR .INTERNATIONAL AC INPUT RANGE .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT .SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED MODEL SPECIFICATION DC OUTPUT VOLTAGE OUTPUT V. TOLERANCE OUTPUT RATED CURRENT OUTPUT CURRENT RANGE PEAK CURRENT RIPPLE & NOISE (p-p) LINE REGULATION LOAD REGULATION DC OUTPUT POWER EFFICIENCY DC VOLTAGE ADJ. INPUT VOLTAGE RANGE AC CURRENT POWER FACTOR OUTPUT GOOD/INPUT POWER FAIL INRUSH CURRENT LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE PROTECTION OVER TEMP. PROTECTION REMOTE CONTROL TEMP. COEFFICIENT SETUP, RISE, HOLD UP TIME VIBRATION WITHSTAND VOLTAGE ISOLATION RESISTANCE WORKING TEMP., HUMIDITY STORAGE TEMP., HUMIDITY DIMENSION WEIGHT SAFETY STANDARDS EMC STANDARDS NOTE : CH1 +5V 1% 30A 3.5-40A 40A 100mV 0.5% 0.8% QP-375-5A CH2 +12V 1% 10A 0-10A 16A 150mV 0.5% 0.8% CH3 12V 1% 6A 0-6A 6A 150mV 0.5% 0.8% CH4 12V 1% 3A 0-3A 3A 50mV 0.5% 0.8% CH1 +5V 1% 30A 3.5-40A 40A 100mV 0.5% 0.8% QP-375-5B CH2 +12V 1% 10A 0-10A 16A 120mV 0.5% 0.8% CH3 12V 1% 6A 0-6A 6A 120mV 0.5% 0.8% CH4 5V 1% 3A 0-3A 3A 50mV 0.5% 0.8% CH1 +5V 1% 30A 3.5-40A 40A 100mV 0.5% 0.8% .ISOLATE CH3 & CH4 DC OUTPUT .MAIN OUTPUT REMOTE SENSE .POWER GOOD AND FAIL SIGNAL
QP-375 SERIES
QP-375-5C CH2 +12V 1% 9A 0-9A 16A 150mV 0.5% 0.8% CH3 15V 1% 4A 0-4A 4A 150mV 0.5% 0.8% CH4 15V 1% 4A 0-4A 4A 240mV 0.5% 0.8%
378W (max.) 77% CH1,2,3,4:+10,-5% 85~264VAC 47~63Hz; 120~370VDC 6A/115V 3A/230V PF>0.95/230VAC, PF>0.98/115VAC 10ms/1ms COLD START 45A <2mA/240VAC
357W (max.) 77% CH1,2,3:+10,-5%
378W (max.) 77% CH1,2,3,4:+10,-5%
105%~135% TYPE: PULSE BY PULSE RESET: AUTO RECOVERY CH1:5.75~6.75V TYPE:SHUTDOWN 80C~5C (TSW1)TYPE:SHUTDOWN RESET:AUTO RECOVERY RC+/RC-:0~0.8V POWER ON ; 4V~10V POWER OFF 0.03% / C (0~50C) 800ms, 50ms, 20ms 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms -10C~+60C(REFER TO OUTPUT DERATING CURVE), 20%~90% RH -20C~+85C, 10%~95% RH 278*127*63.5mm 2.3Kgs UL1950, TUV EN60950 APPROVED CISPR22(EN55022) CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-3-2,3 VERIFICATION
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25C 70% RH. AMBIENT. 2.TOLERANCE : INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. 6.PEAK CURRENT CAN NOT EXCEED 60 SEC. 7.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TATAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 8.ISOLATED CH3 & CH4 MAYBE SERIES CONNECTED OR CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS.
2002-09-23
NEXT ( MECHANICAL INFO )
MEAN WELL
SWITCHING POWER SUPPLY
ISO-9001 CERTIFIED MANUFACTURER
.LOW COST, HIGH RELIABILITY .105C OUTPUT CAPACITOR .INTERNATIONAL AC INPUT RANGE .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT .SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED MODEL SPECIFICATION DC OUTPUT VOLTAGE OUTPUT V. TOLERANCE OUTPUT RATED CURRENT OUTPUT CURRENT RANGE PEAK CURRENT RIPPLE & NOISE LINE REGULATION LOAD REGULATION DC OUTPUT POWER EFFICIENCY DC VOLTAGE ADJ. INPUT VOLTAGE RANGE AC CURRENT POWER FACTOR OUTPUT GOOD/INPUT POWER FAIL INRUSH CURRENT LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE PROTECTION OVER TEMP. PROTECTION REMOTE CONTROL TEMP. COEFFICIENT SETUP, RISE, HOLD UP TIME VIBRATION WITHSTAND VOLTAGE ISOLATION RESISTANCE WORKING TEMP., HUMIDITY STORAGE TEMP., HUMIDITY DIMENSION WEIGHT SAFETY STANDARDS EMC STANDARDS NOTE : CH1 +5V 1% 30A 3.5-40A 40A 100mVp-p 0.5% 0.8% QP-375-5D CH2 +12V 1% 9A 0-9A 16A 120mVp-p 0.5% 0.8% CH3 12V 1% 4A 0-4A 6A 120mVp-p 0.5% 0.8% CH4 24V 1% 3A 0-3A 3A 240mVp-p 0.5% 0.8% CH1 +5V 1% 30A 3.5-40A 40A 100mVp-p 0.5% 0.8% .ISOLATE CH3 & CH4 DC OUTPUT .MAIN OUTPUT REMOTE SENSE .POWER GOOD AND FAIL SIGNAL
QP-375 SERIES
QP-375-5E CH2 +12V 1% 9A 0-9A 16A 120mVp-p 0.5% 0.8% CH3 24V 1% 3A 0-3A 4A 120mVp-p 0.5% 0.8% CH4 24V 1% 2A 0-2A 3A 240mVp-p 0.5% 0.8%
378W (max.) 78% CH1,2,3,4:+10,-5% 85~264VAC 47~63Hz; 120~370VDC 6A/115V 3A/230V PF>0.95/230VAC, PF>0.98/115VAC 10ms/1ms COLD START 45A <2mA/240VAC 105%~135% TYPE: PULSE BY PULSE RESET: AUTO RECOVERY CH1:5.75~6.75V TYPE:SHUTDOWN 80C~5C (TSW1)TYPE:SHUTDOWN RESET:AUTO RECOVERY RC+/RC-:0~0.8V POWER ON ; 4V~10V POWER OFF 0.03% / C (0~50C) 800ms, 50ms, 20ms 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms -10C~+60C(REFER TO OUTPUT DERATING CURVE), 20%~90% RH -20C~+85C, 10%~95% RH 278*127*63.5mm 2.3Kgs UL1950, TUV EN60950 APPROVED
378W (max.) 78% CH1,2,3,4:+10,-5%
CISPR22(EN55022) CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-3-2,3 VERIFICATION
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25C 70% RH. AMBIENT. 2.TOLERANCE : INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. 6.PEAK CURRENT CAN NOT EXCEED 60 SEC. 7.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TATAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 8.ISOLATED CH3 & CH4 MAYBE SERIES CONNECTED OR CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS.
2002-09-23
NEXT ( MECHANICAL INFO )
C OUTPUT CAPACITOR .INTERNATIONAL AC INPUT RANGE .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT -START CIRCUIT, LIMITING AC SURGE CURRENT
.MAIN OUTPUT REMOTE SENSE .POWER GOOD AND FAIL SIGNAL
.SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED QP -375 -24B CH1 +24V O 1% 10A 1 -10A 10A -p) 240mV O 0.5% O 0.8% CH2 +5V O 1% 10A 0 -10A 16A 50mV O 0.5% O 0.8% 386W 78% CH1,2,3,4: O 10% CH3 12V O 1% 4A 0 -4A 4A 120mV O 0.5% O 0.8% CH4 12V O 1% 4A 0 -4A 4A 120mV O 0.5% O 0.8% CH1 +24V O 1% 10A 1 -10A 10A 240mV O 0.5% O 0.8% QP -375 -24C CH2 +5V O 1% 10A 0 -10A 16A 50mV O 0.5% O 0.8% 410W 80% CH1,2,3,4: O 10% CH3 15V O 1% 4A 0 -4A 4A 150mV O 0.5% O 0.8% CH4 15V O 1% 4A 0 -4A 4A 150mV O 0.5% O 0.8%
MODEL SPECIFICATION DC OUTPUT VOLTAGE OUTPUT V. TOLERANCE OUTPUT RATED CURRENT OUTPUT CURRENT RANGE PEAK CURRENT RIPPLE & NOISE (p LINE REGULATION LOAD REGULATION MAX. DC OUTPUT POWER EFFICIENCY DC VOLTAGE ADJ. INPUT VOLTAGE RANGE AC CURRENT INRUSH CURRENT LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE PROTECTION OVER TEMP. PROTECTION TEMP. COEFFICIENT SETUP, RISE, HOLD UP TIME POWER FACTOR REMOTE CONTROL OUTPUT GOOD/INPUT POWER FAIL VIBRATION WITHSTAND VOLTAGE ISOLATION RESISTANCE WORKING TEMP., HUMIDITY STORAGE TEMP., HUMIDITY DIMENSION WEIGHT SAFETY STANDARDS
85~264VAC 47~63Hz; 120~370VDC 6A/115V 3A/230V COLD START 45A <2mA/240VAC 105%~135% TYPE:PULSE BY PULSE RESET:AUTO RECOVERY CH1:27.6~32.4V TYPE:SHUTDOWN 80 C~ O 5 C (TSW1)TYPE:SHUTDOWN RESET:AUTO RECOVERY O 0.03% / C (0~50 C)
800ms, 50ms, 20ms PF>0.95/230VAC, PF>0.98/115VAC RC+/RC -: 0~0.8V POWER ON ; 4V~10V POWER OFF
10ms/1ms
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES I/P -O/P:3KVAC I/P -FG:1.5KVAC O/P -FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms -10 C~+60 -20 C~+85 C(REFER TO OUTPUT DERATING CURVE), 20%~90% RH C, 10%~95% RH
278*127*63.5mm 2.3Kgs UL1950, TUV EN60950 APPROVED CISPR22(EN55022) CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-3-2,3 VERIFICATION
EMC STANDARDS
NOTE :
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25 C 70% RH. AMBIENT. 2.TOLERANCE : INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. 6.PEAK CURRENT CAN NOT EXCEED 60 SEC. 7.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TATAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 8.ISOLATED CH3 & CH4 MAYBE SERIES CONNECTED OR CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS. 2002-09-05


▲Up To Search▲   

 
Price & Availability of QP-375-5E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X